WEKO3
アイテム
{"_buckets": {"deposit": "c182810b-bc28-4118-9625-04bbc0bd5d9d"}, "_deposit": {"created_by": 1, "id": "3251", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "3251"}, "status": "published"}, "_oai": {"id": "oai:yamanashi.repo.nii.ac.jp:00003251", "sets": ["312"]}, "author_link": ["15418", "15419"], "item_10001_alternative_title_1": {"attribute_name": "タイトル(別表記)", "attribute_value_mlt": [{"subitem_alternative_title": "Compliance in the Medical Treatment of Primary Open Angle Glaucoma - newly designed medication monitor -"}]}, "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1987", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "135", "bibliographicPageStart": "125", "bibliographicVolumeNumber": "2", "bibliographic_titles": [{"bibliographic_title": "山梨医科大学雑誌"}, {"bibliographic_title": "山梨医科大学雑誌", "bibliographic_titleLang": "en"}]}]}, "item_10001_creator_2": {"attribute_name": "著者名", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "塚原, 重雄"}], "nameIdentifiers": [{"nameIdentifier": "15418", "nameIdentifierScheme": "WEKO"}]}]}, "item_10001_description_5": {"attribute_name": "内容", "attribute_value_mlt": [{"subitem_description": "Compliance is defined as \"\"the patient is taking the drug as directed by doctor\"\". The direction given by doctors includes general advice, prescribed medication, and schedule appointment. However, in this paper the second subject is dealt with glaucoma treatment. Patient compliance is a major problem in the treatment in primary open angle glaucoma, which causes no pain and disability to encourage the patient to take the treatment. Moreover, this disease requires long-term treatment and follow-up for life. Therefore, it is essential that the drugs are taken regularly to prevent further visual damage. The aim of treatment in primary open angle glaucoma is to maintain good visual function throughout the patient\u0027s life. Physician does not know whether a lack of patient compliance or a lack of drug effectiveness is the cause of deterioration in the disease. Therefore, an objective test to measure compliance is necessary for the treatment of glaucoma patients. To achieve this aim the doctor must regularly check whether the patient is complying with the treatment or not. Several methods have been used to measure compliance, such as interviewing patients, counting remaining pills, measurement of residual volume for the drugs, or measurement of metabolites in urine or blood, and the use of an automatic medication monitor. In these methods the medication monitor gives the most precise and objective information on compliance. The purpose of the present study was to describe the results which our newly designed medication monitors were applied in the medical treatment of primary open angle glaucoma (POAG) patients and to improve methods to measure medication behavior, in order to obtain accurate and reliable information on the patterns of drug-taking in primary open angle glaucoma patients.", "subitem_description_type": "Other"}]}, "item_10001_full_name_24": {"attribute_name": "著者名(別表記)", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "15419", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Tsukahara, Shigeo"}]}]}, "item_10001_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.34429/00003244", "subitem_identifier_reg_type": "JaLC"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "山梨医科大学医学会"}]}, "item_10001_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10044054", "subitem_source_identifier_type": "NCID"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0912-0025", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_text_4": {"attribute_name": "タイトルヨミ", "attribute_value_mlt": [{"subitem_text_value": "ソウセツ リョクナイショウ ヤクブツ リョウホウ ト COMPLIANCE"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-02-27"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "AN10044054_02_04_01.pdf", "filesize": [{"value": "2.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2200000.0, "url": {"label": "AN10044054_02_04_01.pdf", "url": "https://yamanashi.repo.nii.ac.jp/record/3251/files/AN10044054_02_04_01.pdf"}, "version_id": "d7304b9d-e3fe-47db-a31c-c79941f00aa7"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u003c総説\u003e緑内障薬物療法とCOMPLIANCE", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "\u003c総説\u003e緑内障薬物療法とCOMPLIANCE"}]}, "item_type_id": "10001", "owner": "1", "path": ["312"], "permalink_uri": "https://doi.org/10.34429/00003244", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-05-18"}, "publish_date": "2010-05-18", "publish_status": "0", "recid": "3251", "relation": {}, "relation_version_is_last": true, "title": ["\u003c総説\u003e緑内障薬物療法とCOMPLIANCE"], "weko_shared_id": -1}
<総説>緑内障薬物療法とCOMPLIANCE
https://doi.org/10.34429/00003244
https://doi.org/10.34429/000032448efc0b4f-3599-4dfa-8742-8bfdd597a8c7
名前 / ファイル | ライセンス | アクション |
---|---|---|
AN10044054_02_04_01.pdf (2.2 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-05-18 | |||||
タイトル | ||||||
タイトル | <総説>緑内障薬物療法とCOMPLIANCE | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
ID登録 | ||||||
ID登録 | 10.34429/00003244 | |||||
ID登録タイプ | JaLC | |||||
タイトルヨミ | ||||||
ソウセツ リョクナイショウ ヤクブツ リョウホウ ト COMPLIANCE | ||||||
タイトル(別表記) | ||||||
その他のタイトル | Compliance in the Medical Treatment of Primary Open Angle Glaucoma - newly designed medication monitor - | |||||
著者名 |
塚原, 重雄
× 塚原, 重雄 |
|||||
著者名(別表記) | ||||||
姓名 | Tsukahara, Shigeo | |||||
内容 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Compliance is defined as ""the patient is taking the drug as directed by doctor"". The direction given by doctors includes general advice, prescribed medication, and schedule appointment. However, in this paper the second subject is dealt with glaucoma treatment. Patient compliance is a major problem in the treatment in primary open angle glaucoma, which causes no pain and disability to encourage the patient to take the treatment. Moreover, this disease requires long-term treatment and follow-up for life. Therefore, it is essential that the drugs are taken regularly to prevent further visual damage. The aim of treatment in primary open angle glaucoma is to maintain good visual function throughout the patient's life. Physician does not know whether a lack of patient compliance or a lack of drug effectiveness is the cause of deterioration in the disease. Therefore, an objective test to measure compliance is necessary for the treatment of glaucoma patients. To achieve this aim the doctor must regularly check whether the patient is complying with the treatment or not. Several methods have been used to measure compliance, such as interviewing patients, counting remaining pills, measurement of residual volume for the drugs, or measurement of metabolites in urine or blood, and the use of an automatic medication monitor. In these methods the medication monitor gives the most precise and objective information on compliance. The purpose of the present study was to describe the results which our newly designed medication monitors were applied in the medical treatment of primary open angle glaucoma (POAG) patients and to improve methods to measure medication behavior, in order to obtain accurate and reliable information on the patterns of drug-taking in primary open angle glaucoma patients. | |||||
出版者 | ||||||
出版者 | 山梨医科大学医学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0912-0025 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10044054 | |||||
書誌情報 |
山梨医科大学雑誌 en : 山梨医科大学雑誌 巻 2, 号 4, p. 125-135, 発行日 1987 |
|||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |