{"created":"2023-05-18T10:11:45.633118+00:00","id":3543,"links":{},"metadata":{"_buckets":{"deposit":"98fe0167-b407-4b99-ac78-ff4be8e1da1b"},"_deposit":{"created_by":5,"id":"3543","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"3543"},"status":"published"},"_oai":{"id":"oai:yamanashi.repo.nii.ac.jp:00003543","sets":["205:322:340"]},"author_link":[],"item_10001_alternative_title_1":{"attribute_name":"タイトル(別表記)","attribute_value_mlt":[{"subitem_alternative_title":"Bacterial contamination of in-Use hospital Nebulizers","subitem_alternative_title_language":"en"}]},"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"20","bibliographicPageStart":"15","bibliographicVolumeNumber":"9","bibliographic_titles":[{"bibliographic_title":"山梨大学看護学会誌","bibliographic_titleLang":"ja"},{"bibliographic_title":"Yamanashi nursing journal","bibliographic_titleLang":"en"}]}]},"item_10001_creator_2":{"attribute_name":"著者名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"河合, 悦子","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"田辺, 文憲","creatorNameLang":"ja"}]}]},"item_10001_description_5":{"attribute_name":"内容","attribute_value_mlt":[{"subitem_description":"病院で使用中のコンプレッサー型ネブライザー34 台,超音波ネブライザー5 台について細菌汚染に関する調査を行った。コンプレッサー型ネブライザーの連結管については調査した5 病院のすべての病院で再生利用を行っており,嘴管の洗浄は3 病院で食器洗浄機を使用していた。細菌汚染調査を行ったところ,コンプレッサー型ネブライザーの連結管から5 台(15%),エアロゾルから11 台(32%)に一般細菌が検出された。超音波ネブライザーでは作用槽から9 台(100%),薬液槽から7 台(78%),エアロゾルから6 台(67%)に一般細菌が検出された。エアロゾルの細菌汚染はコンプレッサー型ネブライザーでは嘴管の汚染,超音波ネブライザーでは薬液槽の汚染が原因と考えられる。ガラス製嘴管は内部に細菌汚染が残りやすく,薬液槽は加温されているため細菌汚染を受けやすい。そのため,洗浄の前に次亜塩素酸ナトリウムなどの消毒薬に浸漬することが有効ではないかと思われた。","subitem_description_language":"ja","subitem_description_type":"Other"}]},"item_10001_full_name_24":{"attribute_name":"著者名(別表記)","attribute_value_mlt":[{"names":[{"name":"Kawai, Etsuko"}]},{"names":[{"name":"Tanabe, Fuminori"}]}]},"item_10001_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.34429/00003536","subitem_identifier_reg_type":"JaLC"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"山梨大学看護学会","subitem_publisher_language":"ja"}]},"item_10001_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA1180065X","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1347-7714","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-02-27"}],"displaytype":"detail","filename":"YNJ9-1-015to020.pdf","filesize":[{"value":"942.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"YNJ9-1-015to020.pdf","objectType":"fulltext","url":"https://yamanashi.repo.nii.ac.jp/record/3543/files/YNJ9-1-015to020.pdf"},"version_id":"4ae24e9f-e856-4d92-b291-bfeb83f1a892"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"コンプレッサー型ネブライザー"},{"subitem_subject":"超音波ネブライザー"},{"subitem_subject":"Compressor Nebulizer"},{"subitem_subject":"エアロゾル"},{"subitem_subject":"Sonic Nebulizer"},{"subitem_subject":"細菌汚染"},{"subitem_subject":"Aerosol"},{"subitem_subject":"Bacterial Contamination"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"<原著>病院で使用中のネブライザーの細菌汚染の実態","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"<原著>病院で使用中のネブライザーの細菌汚染の実態","subitem_title_language":"ja"}]},"item_type_id":"10001","owner":"5","path":["340"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2011-04-18"},"publish_date":"2011-04-18","publish_status":"0","recid":"3543","relation_version_is_last":true,"title":["<原著>病院で使用中のネブライザーの細菌汚染の実態"],"weko_creator_id":"5","weko_shared_id":-1},"updated":"2023-10-11T08:09:30.670502+00:00"}